auto: docs sync 2026-08-15T12:00:04+00:00

Files changed: engine/.embcache.json engine/changelog.md engine/lint-report.md vault/.obsidian/workspace.json vault/docs/hardware/environment.md vault/projects/fleet-storage-memory-upgrade.md vault/projects/navi-recon-separation.md vault/runbooks/corescope-ingest-stall-oom.md vault/runbooks/edge2-access-reference.md vault/runbooks/edge2-boot-recovery.md vault/runbooks/navi-lift-to-media.md vault/runbooks/peertube-sitemap-redis-oom.md
This commit is contained in:
echo6-autocommit 2026-08-15 12:00:04 +00:00
commit 8f95c6e5c3
12 changed files with 166 additions and 152 deletions

View file

@ -9,8 +9,8 @@ related:
- [[fleet-storage-memory-upgrade]]
- [[ip-allocation]]
- [[toc-cortex-pve9.2-update]]
- [[proxmox-create-ubuntu-vm]]
updated: 2026-08-14
- [[pve-guest-park-and-adopt]]
updated: 2026-08-15
---
# Echo6 Environment Reference
@ -35,7 +35,7 @@ Five nodes running Proxmox VE:
| media | Intel SSDPEKNU512GZH 512GB (NVMe, boot/`pve`) | WD Green SN350 2TB (NVMe, VG `tank`) |
| toc | 512GB NVMe | — |
**media upgraded 2026-08-15:** 32 → 64 GB DDR5-4800 (2 × 32 GB, board maximum reached), and the second M.2 — which held a leftover BitLocker Windows install — replaced with a 2 TB WD Green SN350. That drive is VG `tank` as a **single 1.82 TB volume**`tank/data`, ext4, mounted `/mnt/nvme2tb`, registered as Proxmox dir storage `media-nvme` (`nodes media`-scoped). Deliberately not split into separate pools: navi's geo data is the intended consumer and it needs one large contiguous filesystem it can grow into. The displaced Windows data was archived to pi-nas first — see [[fleet-storage-memory-upgrade]].
**media upgraded 2026-08-15:** 32 → 64 GB DDR5-4800 (2 × 32 GB, board maximum reached), and the second M.2 — which held a leftover BitLocker Windows install — replaced with a 2 TB WD Green SN350. That drive is VG `tank` as a **single 1.82 TB volume**`tank/data`, ext4, mounted `/mnt/nvme2tb`, registered as Proxmox dir storage `media-nvme` (`nodes media`-scoped). Deliberately not split into separate pools: [[navi]]'s geo data is the intended consumer and it needs one large contiguous filesystem it can grow into. The displaced Windows data was archived to pi-nas first — see [[fleet-storage-memory-upgrade]].
**Free positions (verified live 2026-08-14):** data has none — only three external PCIe root ports exist and all are populated (NVMe, NIC, Wi-Fi), and the Wi-Fi M.2 is E-keyed so it cannot take a storage drive. utility and cloud each have an empty 2.5" SATA bay. media's second M.2 holds a leftover BitLocker Windows install (serial `PHKA142402U8512A`; the Proxmox drive is `PHKA142504HP512A`). toc has 8 unpopulated SATA ports and 4 free PCIe slots. pi-nas has one free SATA port (`ata5`). Placement plan is [[fleet-storage-memory-upgrade]].
@ -184,7 +184,7 @@ Current registered nodes (25 total):
| Node | Tailscale IP | Type |
|------|-------------|------|
| contabo | 100.64.0.40 | VPS (edge1, mail-only, rebuilt 2026-06-19; formerly 100.64.0.1) |
| contabo | 100.64.0.40 | VPS (edge1, mail-only, rebuilt [[2026-06-19]]; formerly 100.64.0.1) |
| immich | 100.64.0.2 | LXC |
| media | 100.64.0.3 | Proxmox |
| cloud | 100.64.0.4 | Proxmox |
@ -281,6 +281,6 @@ matt-desktop is accessible via local IP (192.168.1.254) or Tailscale (100.64.0.1
| Purpose | IP |
|---------|-----|
| Home external (public services) | 199.6.36.163 |
| Home external (public [[services]]) | 199.6.36.163 |
| edge1 (mail-only, rebuilt Contabo VPS) | 5.189.158.149 |
| edge2 (front door: vault/forge/notes/auth/matrix/element/vpn/proxmox + idahomesh.com) | 184.174.35.153 |